Oversight at: 
Department of Energy Sites
Formerly Utilized Sites Remedial Action Program (FUSRAP)

Dayton Warehouse, Dayton, Ohio

The Dayton Warehouse is located at 601 East Third Street, at the intersection of East Third and Sears Streets in Dayton, Ohio.  For about three years, between 1946 and 1949, a portion of the Dayton Warehouse was used for MED-related activities. Based on available historical information, Monsanto did not produce Po-210 at the Dayton Warehouse, and only used the fourth, fifth, and sixth floors for the Dayton Project. Initially used to store surplus equipment for the project, a laboratory was later built on
the fifth floor. Warehouse operations reportedly involved only trace amounts of Po-210 from analyses done on environmental samples, personnel bioassay samples, and biological studies on the effects of Po-210 on animals.

Warehouse operations were transferred to the Mound Laboratory in Miamisburg, Ohio in 1948/1949. The Warehouse facility was then decontaminated and returned to the building's manager for rental to other clients. 

In August 1997, the United States Air Force's (USAF's) Radiation Protection Branch found that the exposure rates around the exterior of the Warehouse were at background levels.

In January 2000, the United States Department of Energy (DOE) determined that the Dayton Warehouse was eligible for inclusion into the Formerly Utilized Sites Remedial Action Program (FUSRAP). The constituents of concern at the Warehouse are radium-226 (Ra-226), lead-210 (Pb-210), and beryllium.

The Corps initiated a Site Inspection (SI) in March 2004. The SI involved a systematic assessment of potential fixed and removable residual contamination from the Dayton Warehouse on all six floors, the basement, and the loading area at the north end of
the building. The primary steps in investigation of the Warehouse involved:

• Floor scans and static counts on each floor
• Swipe samples collected and analyzed for the constituents of concern
• Swipe samples collected in each survey grid and field counted
• Three swipe samples on each floor for beryllium analysis
• Three soil samples from the loading area

The sampling at the site found that the radionuclides and lead are similar to background concentrations in southwest Ohio. Based on the findings of the Sit Investigation, the Corps determined that no further action is needed at the Dayton Warehouse Site.

Ohio EPA concurs with the Corps determination.


Read/download the Combined Preliminary Assessment/Site Inspection Report, Dayton Warehouse, September 2005.


For questions concerning FUSRAP sites contact :  Brian Nickel (937.285.6468)